Downloads/ Resources

Crestron Integration

By April 12, 2022 No Comments

Crestron Integration

 

CRESTRON CERTIFIED MODULE

 

Crestron Details:

This module will control the Speaker & Microphone, Volume & Muting, and Dialing features of the Phoenix Octopus Mixer via RS-232.

This module provides control volume and mute control. The module will poll the device for an update at program start. If needed the Poll_Device command can be triggered to update feedback. This module is System Builder ready.

 

Crestron Hardware Required: C2I-COM6, C2NCOM-2/3, CNX-COM6, CNX-COM2, SY-COM
Setup of Crestron Hardware: RS232
Baud: 9600
Parity: None
Data Bits: 8
Stop Bits: 1
Cable Diagram: CNSP-123


Control:

Speaker_Volume_Up D Push to raise speaker volume
Speaker_Volume_Down D Push to lower speaker volume
Speaker_Mute D Pulse to toggle speaker mute
Microphone_Volume_Up D Push to raise microphone volume
Microphone_Volume_Down D Push to lower microphone volume
Microphone_Mute D Pulse to toggle microphone mute
Dialer_(0-9) D Pulse to send (0-9) to telephone dialer
Dialer_* D Pulse to send star to telephone dialer
Dialer_# D Pulse to send pound to telephone dialer
Dialer_Pause D Pulse to send the pause command to the telephone dialer
Dialer_Redial D Pulse to send the redial command to the telephone dialer
Dialer_Flash D Pulse to send the flash command to the telephone dialer
Dialer_On/Off_Hook D Pulse to toggle the on/off hook state for the telephone dialer
Poll_Device D Pulse to poll for device information
From_Device S Serial signal to be routed from RS-232 port

 


Feedback:

Speaker_Volume_Gauge A Analog speaker volume value to be send to the touchpanels gauge
Speaker_Is_Muted D High to indicate that the speaker volume is muted
Microphone_Volume_Gauge A Analog microphone volume value to be send to the touchpanels gauge
Microphone_Is_Muted D High to indicate that the microphone volume is muted
To_Device S Serial signal to be routed to RS-232 port